Electrical Calculators, Practical Guides & EL Tronic Media
Contractor-grade electrical calculators, in-depth engineering guides and electronics repair tutorials in one engineering portal.
Ohm's Law Calculator
Calculate Voltage (V), Current (Amps), Resistance (Ω), and Power (Watts) in single-phase circuits.
Voltage Drop Calculator
Calculates conductor voltage drop percentage according to NEC 3% branch limit standards.
3-Phase Power Calculator
Industrial 480V/208V delta and wye 3-phase real (kW) and apparent (kVA) power calculations.
Cable Size & AWG
Conductor sizing by ampacity, ambient temperature correction factors, and conduit fill.
Motor Current (FLA)
Full Load Amps (FLA) for AC single-phase and 3-phase induction motors with locked rotor amps.
Transformer Sizing
Primary and secondary current ratings, turns ratio, and impedance voltage drops.
HP ↔ kW Converter
Exact conversion between electrical horsepower, mechanical horsepower, and metric kilowatts.
Battery Backup Runtime
Calculate inverter runtime, solar battery bank capacity, and Peukert's exponent adjustments.
Solar PV Array Sizing
Photovoltaic daily solar generation, peak sun hours (PSH), array tilt, and inverter sizing.
LED Series Resistor
Determine current-limiting resistance and resistor wattage rating for single or series LEDs.
Power Factor & kVAR
Determine active, apparent, reactive power, and calculate capacitor bank sizing to reach target PF.
Electricity Cost & kWh
Calculate daily, monthly, and yearly appliance electric power consumption, kWh usage, and utility cost.
Conduit Fill & Capacity
Calculates maximum allowable THHN conductors inside EMT or PVC conduit to comply with NEC 40% limits.
Voltage Unbalance (NEMA)
Percent voltage unbalance, negative-sequence ratio and motor derating from three line voltages.
Motor Efficiency & Losses
Shaft output vs electrical input, typical copper, core and mechanical losses and yearly loss cost.
3-Phase Fault Level
Symmetrical fault MVA, short-circuit kA and first-cycle peak for a substation bus.
VFD Cable & Reflected Wave
Inverter-duty motor cable ampacity, carrier heating and reflected-wave peak voltage.
Grounding Electrode Conductor
Sizes the GEC from the largest service-entrance conductor, with the rod and concrete-encased electrode caps.
Equipment Grounding Conductor
Finds the minimum equipment grounding conductor from the breaker or fuse rating, including 250.122(B) upsizing.
Motor Branch Circuit
Motor FLC from Tables 430.248/250, conductors at 125%, breaker or fuse maximum and overload setting.
Box Fill
Counts conductors, devices, clamps and grounds against the volume of an outlet or junction box.
DC Solar Cable
Sizes 12 V, 24 V and 48 V solar and battery cable for ampacity and voltage drop.
Standby Generator Sizing
Size standby generators for continuous running loads and motor locked-rotor inrush surge.
Short Circuit & AIC Rating
Computes maximum symmetrical short circuit fault current (SCCA) at transformer secondary.
LC Resonant Frequency
Determine resonant frequency and characteristic reactance for LC tank circuits and RF filters.
Capacitor Stored Energy
Calculates stored electrostatic energy in Joules and charge in Coulombs for capacitors.
Voltage Divider
Calculate output voltage, circuit current, and power dissipation in resistor attenuation pairs.
Wheatstone Bridge
Compute differential galvanometric output voltage and balance resistance for bridge sensors.
Electric Space Heating
Determine required heating kW capacity and dedicated 240V circuit breaker sizing for rooms.
Tariff & Peak Demand
Calculate commercial utility bills combining 15-minute peak kW demand charges with kWh usage.
Frequency & Wavelength
Converts frequency to physical wavelength λ and calculates quarter-wave antenna whip length.
RC Time Constant
Calculate RC charging/discharging time constant τ (63.2% threshold) and 5τ full charge time.
RL Time Constant
Calculate RL circuit time constant τ, magnetic field rise time, and stored energy.
Decibel (dBm / dBu / dBV)
Convert RF power in milliwatts to dBm, and AC signal voltages to dBu / dBV levels.
AC Skin Effect & Depth
Calculates AC skin depth penetration in copper and aluminum conductors across operating frequencies.
Transformer Turns Ratio
Calculate primary to secondary turns ratio, output voltage step-down/up, and current scaling.
Delta-Wye (Δ-Y) Conversion
Convert 3-phase balanced or unbalanced delta resistor networks to equivalent wye configurations.
Series & Parallel Networks
Calculate total equivalent resistance and total equivalent capacitance for series/parallel combinations.
OP-AMP Voltage Gain
Non-inverting and inverting operational amplifier closed-loop voltage gain and output voltage.
Inductive Reactance (X_L)
Calculates AC inductive reactance in ohms and stored magnetic energy in Joules.
Capacitive Reactance (X_C)
Calculate AC capacitive reactance in ohms for power supply decoupling and AC filtering.
Meter Pulse & Instant Load
Calculate real-time power consumption from utility meter disk Kh or optical LED flashes.
Copper & Al Busbar Capacity
Determine maximum ampacity rating for solid copper and aluminum electrical busbars.
Ground Rod Resistance
Calculates grounding electrode resistance to earth based on soil resistivity (Ω·m) per IEEE 80.
PCB Trace Width (IPC-2221)
Calculate required printed circuit board copper trace width for target current and temperature rise.
NE555 Timer Astable
Calculate pulse frequency, period, high/low time, and duty cycle for NE555 timer IC circuits.
3-Phase Unbalanced Neutral
Calculates neutral conductor current flow resulting from unbalanced 3-phase 4-wire loads.
Solar Inverter Output
Calculate AC output power, DC array clipping loss, and weighted CEC inverter efficiency.
EV Charging Time
Calculate EV battery charging duration for Level 1 (120V), Level 2 (240V AC), and Level 3 DC Fast Charging.
Motor Torque & Power
Shaft torque in N·m and lb·ft from motor power and speed, with efficiency, losses and shaft shear stress.
Motor Slip & Speed
Synchronous speed, slip percentage and rotor frequency from supply frequency, poles and rotor speed.
VFD Frequency & Speed
Shaft rpm, V/Hz voltage and low-speed torque derating for constant- and variable-torque loads.
Motor Inrush & LRA
Starting inrush for direct-on-line, star-delta and soft-starter methods with breaker pickup guidance.
Motor Run Capacitor
Run and start capacitor sizing in µF with minimum AC working voltage for single-phase motors.
Brake Resistor Calculator
Dynamic braking resistance in ohms and continuous watt rating from DC bus voltage, regen power and duty.
Motor Power from Run Cap
Determine single-phase motor power in Watts, HP, and kW given its run capacitor microfarad (µF) rating.
Motor Start Capacitor
Calculate starting capacitor rating (µF) for high starting torque CSCR / CSIR single-phase motors.
Motor Power from Start Cap
Determine motor power rating in Watts, HP, and kW given its start capacitor microfarad (µF) rating.
Total Harmonic Distortion (THD)
Calculates total voltage and current harmonic distortion percentage according to IEEE 519 standards.
Transformer Efficiency & Loss
Calculate transformer operating efficiency, core losses, copper losses, and peak efficiency load point.
Open-Delta (V-V) Capacity
Determine continuous 3-phase capacity using two single-phase transformers in emergency open-delta.
Substation Earthing Grid
Calculate substation grounding grid resistance based on soil resistivity, grid area, and conductor length.
Cable Fault Withstand Size
Calculate minimum conductor cross-section (mm²) to withstand fault current thermal stress per IEC 60364-5-54.
Motor Locked Rotor Amps
Calculate motor starting inrush current (LRA) using NEMA code letter kVA/HP classifications.
Star-Delta Transition Timer
Calculate motor run-up acceleration time and recommended Star to Delta switching timer delay.
Thermal Overload Relay
Calculate motor thermal overload relay setting and trip class timing according to NEC standards.
VFD Motor Speed & Slip
Calculate synchronous speed, actual rotor RPM, and slip percentage across variable VFD operating frequencies.
Solar String Cold Voc
Calculate maximum expected cold open-circuit voltage for solar strings at lowest ambient site temperature.
Solar Charge Controller
Calculate required charge controller ampacity and determine optimal MPPT or PWM technology selection.
Battery Peukert Capacity
Calculate actual battery runtime and effective usable capacity under continuous high-discharge current loads.
EV Charger Circuit Sizing
Calculate breaker size and minimum conductor gauge for Level 2 EV charging stations per NEC Article 625.
Surge Protection Device (SPD)
Calculate continuous operating voltage (Uc) and surge discharge capacity (In/Imax) for distribution panels.
Indoor Lighting Lumen Count
Calculate required number of LED luminaires to achieve target illuminance (Lux) in indoor rooms.
Breaker Selectivity Margin
Evaluate overcurrent breaker selectivity coordination ratio to prevent upstream main breaker nuisance trips.
Zener Voltage Regulator
Calculate series limiting resistor value (Ω) and max Zener diode power dissipation (mW) for shunt regulators.
Heatsink Thermal Sizing
Calculate maximum allowable heatsink thermal resistance (°C/W) to prevent semiconductor thermal destruction.
Ferrite Core Inductor Turns
Calculate magnet wire turns count N for toroidal and bobbin ferrite cores using manufacturer A_L inductance factors.
Transformer K-Factor
Calculate K-Factor rating from non-linear load harmonic currents to prevent transformer neutral and core overheating.
RF / Audio Attenuator Pad
Calculate resistor values (Ω) for symmetrical T-Pad and Pi-Pad impedance-matched signal attenuators.
Appliance Energy Cost
Daily, monthly and yearly running cost of any appliance with duty cycle and standby draw.
Generator Fuel Consumption
Diesel, gas and LPG fuel use versus load, with cost per kWh generated.
Power Factor Penalty
Utility penalty for low power factor, kVA billing comparison and capacitor payback.
LED Savings & Payback
LED retrofit ROI with relamping labor, cooling-load credit and simple payback.
Battery Bank Storage
Ah and kWh sizing with autonomy, DoD and lead-acid versus LiFePO4 comparison.
Grid-Tie Inverter Sizing
DC/AC ratio, clipping loss and MPPT string window matching.
EV Range & Charging Cost
EV cost per mile versus gasoline with break-even electricity and fuel prices.
Solar Wire Voltage Drop
PV string and DC cable voltage drop with AWG and mm² selection.
Solar Tilt & Azimuth
Optimum tilt, true azimuth and winter-solstice row spacing for a site latitude.
555 Timer Monostable
One-shot pulse width from R and C with trigger and loading checks.
Capacitor Series & Parallel
Equivalent capacitance and voltage sharing across series capacitors.
Inductor Series & Parallel
Equivalent inductance with mutual coupling and coupling-factor extraction.
VSWR & Return Loss
Reflection coefficient, VSWR, return loss and mismatch loss.
Microstrip Impedance
Characteristic impedance and effective dielectric constant from PCB trace geometry.
Dipole Antenna Length
Half-wave dipole and quarter-wave lengths with velocity-factor adjustment.
Friis & Path Loss
Free-space path loss, received power and link margin for an RF link.
Engineering & Metrology Guides
12 in-depth technical articles, mathematical derivations, NEC standards, and scientific calibration references.
EL Tronic — Electrical & Electronics Projects
Tutorials, component guides, and repair walkthroughsLatest Videos
Watch our latest electronics tutorials, reviews, and how-to guides.
No videos yet. Add videos from the Admin Panel.